Diasys 3 plus

Hybrid Oscillometric and Auscultatory ABPM

THE MOST ADVANCED HYBRID ABPM DELIVERING SUPERIOR ACCURACY

The Diasys 3 plus is a Unique Hybrid Oscillometric and Auscultatory ABPM with an advanced algorithm utilising ‘NovaPrecision’ and ‘NovaComfort’ technologies to provide give you the best possible results whilst maximising patient comfort and compliance.

TRIPLE-SENSOR TECHNOLOGY DELIVERING:

Integrated accelerometer and barometer provide information on patient position and movement. This allows additional BP measurement to be made based on changes in the patient’s posture to enable the investigation of Orthostatic Hypotension.

The Diasys 3 is an oscillometric ABPM with an advanced algorithm utilising “NovaPrecision” and “NovaComfort” technologies to provide give you the best possible results whilst maximising patient comfort and compliance.

With an ergonomic conical cuff the Diasys 3 offers many innovations to improve comfort:
Dynamic maximum cuff pressure, automatically calculated during inflation.
Rapid and completely smooth deflation.
Unique “Night Mode” for improved silence and comfort during sleep.

Fully compatible with our advanced software



DUAL SENSOR PATCH – THE ULTIMATE ACCESSORY

24hr Arterial Compliance / Qkd

Assessing Cardiac Risk with QKd
In a cohort of 412 patients, QKd has been shown to have a direct correlation with cardiovascular risk. It is the Only Clinically Validated and reproducible, ambulatory measurement of Arterial Stiffness or Compliance.
“Independent of Blood Pressure ambulatory measurement of the QKd interval showed that an increase in arterial stiffness was a marker of cardiovascular risk.”*
*Arterial stiffness evaluated by measurement of the QKd interval is an independent predictor of cardiovascular events. Am J Hypertension (2005)

Central Blood Pressure

Clinically validated by an invasive study on 145 patients.
The measurement of central blood pressure has become a matter of growing importance, it may explain why different anti-hypertensive strategies, that achieve similar improvements
in brachial blood pressure, seem to lead to different reductions in cardiovascular risk.
Our new non-invasive method for the automatic measurement of Central Blood pressure is based on both the highly accurate brachial blood pressure and associated QKd interval.
Determination of central blood pressure by a noninvasive method BP and QKd interval). – J. Hypertension (2012)

Enhanced Position Information

Corroborate and enhanced the embedded Accelerometer and Barometer assessment of patient positional changes and activity.

 

X